Показать сокращенную информацию
dc.contributor.author | Pasynkov D.V. | |
dc.contributor.author | Tukhbatullin M.G. | |
dc.contributor.author | Egoshin I.A. | |
dc.contributor.author | Kolchev A.A. | |
dc.contributor.author | Kliouchkin I.V. | |
dc.date.accessioned | 2022-02-09T20:43:46Z | |
dc.date.available | 2022-02-09T20:43:46Z | |
dc.date.issued | 2021 | |
dc.identifier.uri | https://dspace.kpfu.ru/xmlui/handle/net/169867 | |
dc.description.abstract | Purpose. To compare the results of screening ultrasound (US) in women with dense (ACR C-D) breast parenchyma, with no suspicious changes at mammography, with and without considering the CAD results during the examination. Materials and methods. We randomized 2078 women aged 40-72 years old for breast US (US group) or CAD + breast US with targeted analysis of the areas marked by CAD on the mammograms (CAD + US group). Results. In the US group we found 16 breast carcinomas (BC) (median: 15 mm, range: 8-24 mm), in the CAD + US group - 22 BCs (median: 10 mm, range: 5-24 mm). 3 of the 16 BCs (18.75%) in the US group and 11 of 22 (50.00%) BCs in the CAD + US group (p<0.05) were less than 1 cm. BCs were revealed only during the targeted scanning of the CAD marking area in 5 of 11 women, and all these BCs were ≤1 CM. The rate of benign le-sions required biopsy was 76 of 1039 (7.31%) - in the US group and 68 of 1039 (6.54%) - in the CAD + US group (p>0.05). During the 3-year follow up we found 9 more BCs in the US group and 2 more BCs in the CAD + US group (p<0,05). Discussion. The probability of ACR C-D parenchyma in another sample of 10000 mammography sets was: 51.61% - in women of 40-44 years old, 37.10% - in women of 45-49 years old, 13.22% - in women of 50-54 years old, 12.07% - in women of 55-59 years old, 8.41% - ≥60 years old. Conclusion. In the mammographically dense breast parenchyma the targeted ultra-sound of the areas marked by CAD as suspicious significantly increased the small BCs de-tectability and significantly decreased the rate of BCs revealed during the 3-year follow up with no raise of unnecessary biopsy rate. | |
dc.subject | Breast carcinoma | |
dc.subject | Computer-aided detection system | |
dc.subject | Dense breast | |
dc.subject | Mammography | |
dc.subject | Screening | |
dc.subject | Ultra-sound | |
dc.title | Ultrasound breast cancer screening in dense parenchyma: The value of computer aided detection system for mammography (single-center, prospective, randomized clinical trial) | |
dc.type | Article | |
dc.relation.ispartofseries-issue | 1 | |
dc.relation.ispartofseries-volume | 11 | |
dc.collection | Публикации сотрудников КФУ | |
dc.relation.startpage | 103 | |
dc.source.id | SCOPUS-2021-11-1-SID85105821979 |