Электронный архив

Amperometric sensor based on MWNT and electropolymerized carminic acid for the simultaneous quantification of TBHQ and BHA

Показать сокращенную информацию

dc.contributor.author Ziyatdinova G.
dc.contributor.author Guss E.
dc.contributor.author Budnikov H.
dc.date.accessioned 2021-02-25T20:43:50Z
dc.date.available 2021-02-25T20:43:50Z
dc.date.issued 2020
dc.identifier.issn 1572-6657
dc.identifier.uri https://dspace.kpfu.ru/xmlui/handle/net/162332
dc.description.abstract © 2020 Elsevier B.V. Amperometric sensor based on the layer-by-layer combination of multi-walled carbon nanotubes and electropolymerized carminic acid deposited on the glassy carbon electrode surface (poly(carminic acid)/MWNT/GCE) has been developed for the simultaneous quantification of tert-butylhydroquinone (TBHQ) and butylated hydroxyanisole (BHA). Conditions of poly(carminic acid) coverage obtaining have been found on the basis of TBHQ and BHA peak potential separation and oxidation currents. The best parameters have been observed for poly(carminic acid) electrodeposited from 50 μmol L−1 monomer solution by seven-fold cycling of potential in the range of 0.3–0.8 V with the scan rate of 50 mV s−1 in Britton-Robinson buffer (BRB) pH 2.0. Electrodes have been characterized by scanning electron microscopy (SEM) and electrochemical methods. Good resolution of TBHQ and BHA oxidation potentials equalled to 190 mV has been obtained on the poly(carminic acid)/MWNT/GCE vs. 146 mV on MWNT/GCE. The oxidation currents are 2.1- and 1.8-fold increased on polymer-modified electrode for TBHQ and BHA, respectively. Parameters of TBHQ and BHA electrooxidation on poly(carminic acid)/MWNT/GCE have been calculated. Sensor response is linear in the range of 0.50–75 μmol L−1 for TBHQ and 0.25–75 μmol L−1 for BHA with the limits of detection of 0.36 and 0.23 μmol L−1, respectively. Sensor selectivity in the presence of inorganic ions, ascorbic acid and α-tocopherol is confirmed. The sensor developed has been tested on the linseed oil. The recovery of 100–103% confirm high accuracy of the approach.
dc.relation.ispartofseries Journal of Electroanalytical Chemistry
dc.subject BHA
dc.subject Carminic acid
dc.subject Electropolymerization
dc.subject Modified electrodes
dc.subject TBHQ
dc.subject Voltammetry
dc.title Amperometric sensor based on MWNT and electropolymerized carminic acid for the simultaneous quantification of TBHQ and BHA
dc.type Article
dc.relation.ispartofseries-volume 859
dc.collection Публикации сотрудников КФУ
dc.source.id SCOPUS15726657-2020-859-SID85078490630


Файлы в этом документе

Данный элемент включен в следующие коллекции

  • Публикации сотрудников КФУ Scopus [24551]
    Коллекция содержит публикации сотрудников Казанского федерального (до 2010 года Казанского государственного) университета, проиндексированные в БД Scopus, начиная с 1970г.

Показать сокращенную информацию

Поиск в электронном архиве


Расширенный поиск

Просмотр

Моя учетная запись

Статистика