dc.contributor.author |
Koga Y. |
|
dc.contributor.author |
Povalko N. |
|
dc.contributor.author |
Inoue E. |
|
dc.contributor.author |
Ishii A. |
|
dc.contributor.author |
Fujii K. |
|
dc.contributor.author |
Fujii T. |
|
dc.contributor.author |
Murayama K. |
|
dc.contributor.author |
Mogami Y. |
|
dc.contributor.author |
Hata I. |
|
dc.contributor.author |
Ikawa M. |
|
dc.contributor.author |
Fukami K. |
|
dc.contributor.author |
Fukumoto Y. |
|
dc.contributor.author |
Nomura M. |
|
dc.contributor.author |
Ichikawa K. |
|
dc.contributor.author |
Yoshida K. |
|
dc.date.accessioned |
2021-02-25T20:33:54Z |
|
dc.date.available |
2021-02-25T20:33:54Z |
|
dc.date.issued |
2020 |
|
dc.identifier.issn |
0141-8955 |
|
dc.identifier.uri |
https://dspace.kpfu.ru/xmlui/handle/net/161750 |
|
dc.description.abstract |
© 2020 The Authors. Journal of Inherited Metabolic Disease published by John Wiley & Sons Ltd on behalf of SSIEM. Mitochondrial diseases (MDs) are occasionally difficult to diagnose. Growth differentiation factor 15 (GDF15) has been reported as a biomarker useful for not only diagnosing MDs, but also evaluating disease severity and therapeutic efficacy. To enable the measurement of serum GDF15 concentrations at medical institutions, we developed a new latex-enhanced turbidimetric immunoassay (LTIA) as an automated diagnostic indication test for MDs. We also examined the equivalency of specificity and sensitivity in measuring serum GDF15 concentrations between a commercially available enzyme-linked immunosorbent assay (ELISA) kit and a novel LTIA device in patients with MDs, disease controls, and healthy controls. A clinical performance study used a newly developed LTIA device and an existing ELISA kit to measure the concentrations of GDF15 in 35 MD patients, 111 disease controls, and 86 healthy controls. The median (first quartile-third quartile) of serum GDF15 concentrations measured with the LTIA device was significantly higher (P <.001) in MD patients (1389.0 U/mL [869.5-1776.0 U/mL]) than in healthy controls (380.5 U/mL [330.2-471.8 U/mL]); the interquartile ranges did not overlap between MD patients and healthy controls. The areas under the curve in disease and healthy controls were 0.812 (95% confidence interval [CI]: 0.734-0.886) and 0.951 (95% CI: 0.910-0.992), respectively. The automated, high-throughput technology-based LTIA device has definite advantages over the ELISA kit in shorter processing time and lower estimated cost per sample measurement. The LTIA device of GDF15 may be a sufficiently reliable, frontline, diagnostic indicator of individuals with suspected MDs in the general population. |
|
dc.relation.ispartofseries |
Journal of Inherited Metabolic Disease |
|
dc.subject |
biomarker |
|
dc.subject |
diagnostic indication device |
|
dc.subject |
GDF15 |
|
dc.subject |
latex |
|
dc.subject |
LTIA |
|
dc.subject |
mitochondrial disease |
|
dc.title |
A new diagnostic indication device of a biomarker growth differentiation factor 15 for mitochondrial diseases: From laboratory to automated inspection |
|
dc.type |
Article |
|
dc.collection |
Публикации сотрудников КФУ |
|
dc.source.id |
SCOPUS01418955-2020-SID85092102093 |
|