Full compensation of reactive power in electric networks 0.4-10kV

Показать сокращенную информацию

dc.contributor.author Nazarychev S.A.
dc.contributor.author Akhmetshin A.R.
dc.contributor.author Gaponenko S.O.
dc.date.accessioned 2021-02-25T06:51:56Z
dc.date.available 2021-02-25T06:51:56Z
dc.date.issued 2020
dc.identifier.issn 1742-6588
dc.identifier.uri https://dspace.kpfu.ru/xmlui/handle/net/161163
dc.description.abstract © 2020 Published under licence by IOP Publishing Ltd. The most important task in electric networks is to reduce energy losses. According to Network Company, in distribution electric networks with a voltage of 0.4-10 kV, they account for 62% of the total number of losses. One way to save energy is reactive power compensation. From Order of the Ministry of Energy of the Russian Federation dated June 23, 2015 No. 380 "On the Procedure for Calculation of the Ratio of Consumption of Active and Reactive Power for Individual Energy Receiving Devices (Groups of Energy Receiving Devices) of Electric Power Consumers" at a voltage of 0.4 kV, the reactive power coefficient should not exceed the value 0.35, and on the side of 10 kV-values of 0.4. In practice, in distribution electric networks, reactive power compensation devices are not installed in most cases, and the reactive power factor is 2-3 times higher than the standard values. Since compensating devices are expensive equipment, it is necessary to evaluate the feasibility of deep reactive power compensation, in the range of reactive power factor changes from its standard value to zero. The article discusses the economic and technical feasibility of deep reactive power compensation. The use of a generalized parameter of the electric network for determining the voltage at substations of distribution electric networks is proposed. The need for the coordinated use of reactive power compensation devices and booster transformers to ensure the quality of electricity is shown.
dc.relation.ispartofseries Journal of Physics: Conference Series
dc.title Full compensation of reactive power in electric networks 0.4-10kV
dc.type Conference Paper
dc.relation.ispartofseries-issue 1
dc.relation.ispartofseries-volume 1588
dc.collection Публикации сотрудников КФУ
dc.source.id SCOPUS17426588-2020-1588-1-SID85090768108