Kazan Federal University Digital Repository

Electrochemical Aptasensor with Layer-by-layer Deposited Polyaniline for Aflatoxin M1 Voltammetric Determination

Show simple item record

dc.contributor.author Kulikova T.
dc.contributor.author Porfireva A.
dc.contributor.author Evtugyn G.
dc.contributor.author Hianik T.
dc.date.accessioned 2020-01-21T20:45:23Z
dc.date.available 2020-01-21T20:45:23Z
dc.date.issued 2019
dc.identifier.issn 1040-0397
dc.identifier.uri https://dspace.kpfu.ru/xmlui/handle/net/157738
dc.description.abstract © 2019 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim Mycotoxins are highly toxic metabolites of some fungi that frequently contaminate water, food and feed and hence cause several human and animal diseases. In this work, a new approach to the fast and reliable determination of aflatoxin M1 (AFM1) in water and milk has been proposed with reagent free protocol of signal measurement. For this purpose, DNA aptamer selective to AFM1 was entrapped between two thin layers of polyaniline (PANI) electrodeposited on glassy carbon electrode. The incubation of the aptasensor in the AFM1 solution results in remarkable decrease of the PANI intrinsic activity monitored by direct current voltammetry or electrochemical impedance spectroscopy. Appropriate calibration curves were linear in the range from 3 to 90 ng/L with limit of detection (LOD) 1–5 ng/L depending on the measurement mode. Mechanism of signal generation involves shielding electrostatic interactions between the PANI and aptamer in the surface layer and variation of its redox activity attributed to the emeraldine form of PANI. Selectivity of the response was proved by similar experiments with aflatoxin B1 and ochratoxin A and by comparison of the results with those obtained with non-specific aptamer in the sensing layer. Simple protocol for milk pretreatment has been proposed for reliable detection of AFM1 on the level of its threshold limited values (20 ng/L).
dc.relation.ispartofseries Electroanalysis
dc.subject Aflatoxin M1
dc.subject DNA aptamer
dc.subject Electrochemical impedance spectroscopy
dc.subject Electropolymerization
dc.subject Polyaniline
dc.title Electrochemical Aptasensor with Layer-by-layer Deposited Polyaniline for Aflatoxin M1 Voltammetric Determination
dc.type Article
dc.relation.ispartofseries-issue 10
dc.relation.ispartofseries-volume 31
dc.collection Публикации сотрудников КФУ
dc.relation.startpage 1913
dc.source.id SCOPUS10400397-2019-31-10-SID85067402098


Files in this item

This item appears in the following Collection(s)

  • Публикации сотрудников КФУ Scopus [24551]
    Коллекция содержит публикации сотрудников Казанского федерального (до 2010 года Казанского государственного) университета, проиндексированные в БД Scopus, начиная с 1970г.

Show simple item record

Search DSpace


Advanced Search

Browse

My Account

Statistics