Электронный архив

Analysis of the controllability of the natural draft cooling tower

Показать сокращенную информацию

dc.contributor.author Badriev A.
dc.contributor.author Sharifullin V.
dc.date.accessioned 2020-01-15T21:47:59Z
dc.date.available 2020-01-15T21:47:59Z
dc.date.issued 2019
dc.identifier.issn 1546-1955
dc.identifier.uri https://dspace.kpfu.ru/xmlui/handle/net/156034
dc.description.abstract Copyright © 2019 American Scientific Publishers All rights reserved The most important performance indicators of thermal and nuclear power plants depend on the technological characteristics of natural draught cooling towers. However, those apparatuses are often operated in terms of their low efficiency. One of the reasons for the decline in natural draught cooling tower performance may be uneven distribution of flows. A comprehensive study of the operating characteristics of a natural draught cooling tower under the conditions of uneven distribution of water and air flows through the sections of the apparatus has been carried out. There are four main factors (parameters) affecting the air flow in each section of the apparatus: the temperature difference between the incoming water for cooling and atmospheric air, the hydrodynamic resistance coefficient of the section, the water concentration in it and the wind speed in the immediate vicinity of the air supplying windows. Field studies of the effect of wind speed on the distribution of air flow in sections of a natural draught cooling tower were carried out. A qualitative analysis has been made concerning the influence of the degree of air supplying windows opening on the air flow rate in a natural draught cooling tower. Based on this analysis, an assumption has been made about the extremity of this characteristic at critical wind speeds, which can be taken into account when developing a natural draught cooling tower control system. The results of the work can be used in the development of an automated contro l system for the apparatus.
dc.relation.ispartofseries Journal of Computational and Theoretical Nanoscience
dc.subject Aerodynamic Characteristics
dc.subject Air Consumption
dc.subject Control
dc.subject Natural Draught Cooling Tower
dc.subject Process Non-Uniformity
dc.subject Regression Equations
dc.title Analysis of the controllability of the natural draft cooling tower
dc.type Article
dc.relation.ispartofseries-issue 1
dc.relation.ispartofseries-volume 16
dc.collection Публикации сотрудников КФУ
dc.relation.startpage 213
dc.source.id SCOPUS15461955-2019-16-1-SID85064260927


Файлы в этом документе

Данный элемент включен в следующие коллекции

  • Публикации сотрудников КФУ Scopus [24551]
    Коллекция содержит публикации сотрудников Казанского федерального (до 2010 года Казанского государственного) университета, проиндексированные в БД Scopus, начиная с 1970г.