dc.description.abstract | © 2019, Pleiades Publishing, Ltd. Abstract: A method is developed for the flow-injection amperometric determination of tryptophane and pyridoxine on a screen-printed electrode with electrodeposited gold nanoparticles. The dependence of the analytical signal on the concentrations of tryptophane and pyridoxine on the logarithmic coordinates is linear in the ranges from 5 × 10−7 to 5 × 10−3 and from 5 × 10−8× to 5 × 10–3 M, respectively. A possibility of the simultaneous amperometric determination of tryptophane and pyridoxine on a dual screen-printed electrode modified by gold nanoparticles in a flow-injection system is shown. The developed method is approved in the determination of tryptophane and pyridoxine in medicinal preparations. | |
dc.relation.ispartofseries | Journal of Analytical Chemistry | |
dc.subject | chemically modified electrodes | |
dc.subject | dual screen-printed electrode | |
dc.subject | electrooxidation of tryptophane and pyridoxine | |
dc.subject | flow-injection analysis | |
dc.subject | gold nanoparticles | |
dc.title | Amperometric Detection of Tryptophane and Pyridoxine on a Dual Screen-Printed Electrode Modified by Gold Nanoparticles in a Flow-Injection System | |