Показать сокращенную информацию
dc.contributor.author | Shaidarova L. | |
dc.contributor.author | Chelnokova I. | |
dc.contributor.author | Il'ina M. | |
dc.contributor.author | Gedmina A. | |
dc.contributor.author | Budnikov H. | |
dc.date.accessioned | 2018-09-19T22:50:43Z | |
dc.date.available | 2018-09-19T22:50:43Z | |
dc.date.issued | 2016 | |
dc.identifier.uri | https://dspace.kpfu.ru/xmlui/handle/net/145615 | |
dc.description.abstract | It is found that the mixed-valence ruthenium and cobalt oxides (CoOx-RuOx) composite electrodeposited on screen printed electrode exhibits catalytic activity during caffeine and paracetamol electrooxidation. These compounds are oxidized at different potentials which provides selective voltammetric determination at simultaneous presence. A method of amperometric determination of caffeine and paracetamol on a dual electrode modified with CoOx-RuOx composite in a flow injection analysis is developed. The linear relationship between an analytical signal and analyte concentration is found in the range from 5×10-7 mol/l to 5×10-3 mol/l. Using a modified dual screen printed electrode as an amperometric detector in flow injection analysis allows to determine up to 360 samples/hour. The developed method has been tested in the analysis of some pharmaceuticals. | |
dc.subject | Caffeine and paracetamol electrooxidation | |
dc.subject | Chemically modified electrodes | |
dc.subject | Flow injection analysis of pharmaceuticals | |
dc.subject | Mixed-valence ruthenium and cobalt oxides | |
dc.subject | Modified dual screen printed electrode | |
dc.title | Amperometric detection of caffeine and paracetamol on a dual screen printed electrode modified with mixed-valence ruthenium and cobalt oxides in flow-injection analysis | |
dc.type | Article | |
dc.relation.ispartofseries-issue | 6 | |
dc.relation.ispartofseries-volume | 7 | |
dc.collection | Публикации сотрудников КФУ | |
dc.relation.startpage | 2884 | |
dc.source.id | SCOPUS-2016-7-6-SID85018207653 |