Электронный архив

Optimization of cytochrome c detection by acoustic and electrochemical methods based on aptamer sensors

Показать сокращенную информацию

dc.contributor.author Poturnayova A.
dc.contributor.author Castillo G.
dc.contributor.author Subjakova V.
dc.contributor.author Tatarko M.
dc.contributor.author Snejdarkova M.
dc.contributor.author Hianik T.
dc.date.accessioned 2018-09-19T20:39:43Z
dc.date.available 2018-09-19T20:39:43Z
dc.date.issued 2017
dc.identifier.issn 0925-4005
dc.identifier.uri https://dspace.kpfu.ru/xmlui/handle/net/143100
dc.description.abstract © 2016 Elsevier B.V.We report the effect of various factors such as oligonucleotide sequence, buffer composition, ionic strength for optimal determination of cytochrome c (cyt c) by DNA aptamer sensors using thickness shear mode acoustics (TSM) and electrochemical methods. Up to now, several DNA aptamers specific to cyt c have been selected and used in various sensing approaches including optical, electrochemical and mass sensitive transducers. We have analyzed the response of three different aptamers immobilized via biotin-neutravidin method on a gold support by TSM technique. Using this approach we have shown that only 76-length base sequence (apt 76) exhibited specific binding to cyt c with detection limit of 0.50 ± 0.05 nM. This aptamer was then studied under different ionic conditions showing an optimal response for HEPES buffer. Apt 76 based sensor has been also examined by electrochemical methods. However due to the electroactive nature of cyt c, the response of this aptamer was less favorable in comparison with TSM. The apt 76 based sensor was tested also in spiked samples of human plasma by TSM achieving a recovery of 92 ± 6.6% for 1 nM cyt c.
dc.relation.ispartofseries Sensors and Actuators, B: Chemical
dc.subject Cyclic voltammetry
dc.subject Cytochrome c
dc.subject DNA aptamer
dc.subject Electrochemical impedance spectroscopy
dc.subject Thickness shear mode
dc.title Optimization of cytochrome c detection by acoustic and electrochemical methods based on aptamer sensors
dc.type Article
dc.relation.ispartofseries-volume 238
dc.collection Публикации сотрудников КФУ
dc.relation.startpage 817
dc.source.id SCOPUS09254005-2017-238-SID84990927933


Файлы в этом документе

Данный элемент включен в следующие коллекции

  • Публикации сотрудников КФУ Scopus [24551]
    Коллекция содержит публикации сотрудников Казанского федерального (до 2010 года Казанского государственного) университета, проиндексированные в БД Scopus, начиная с 1970г.

Показать сокращенную информацию

Поиск в электронном архиве


Расширенный поиск

Просмотр

Моя учетная запись

Статистика