Kazan Federal University Digital Repository

Planck 2015 results: VIII. High Frequency Instrument data processing: Calibration and maps

Show simple item record

dc.contributor.author Adam R.
dc.contributor.author Ade P.
dc.contributor.author Aghanim N.
dc.contributor.author Arnaud M.
dc.contributor.author Ashdown M.
dc.contributor.author Aumont J.
dc.contributor.author Baccigalupi C.
dc.contributor.author Banday A.
dc.contributor.author Barreiro R.
dc.contributor.author Bartolo N.
dc.contributor.author Battaner E.
dc.contributor.author Benabed K.
dc.contributor.author Benoît A.
dc.contributor.author Benoit-Lévy A.
dc.contributor.author Bernard J.
dc.contributor.author Bersanelli M.
dc.contributor.author Bertincourt B.
dc.contributor.author Bielewicz P.
dc.contributor.author Bock J.
dc.contributor.author Bonavera L.
dc.contributor.author Bond J.
dc.contributor.author Borrill J.
dc.contributor.author Bouchet F.
dc.contributor.author Boulanger F.
dc.contributor.author Bucher M.
dc.contributor.author Burigana C.
dc.contributor.author Calabrese E.
dc.contributor.author Cardoso J.
dc.contributor.author Catalano A.
dc.contributor.author Challinor A.
dc.contributor.author Chamballu A.
dc.contributor.author Chiang H.
dc.contributor.author Christensen P.
dc.contributor.author Clements D.
dc.contributor.author Colombi S.
dc.contributor.author Colombo L.
dc.contributor.author Combet C.
dc.contributor.author Couchot F.
dc.contributor.author Coulais A.
dc.contributor.author Crill B.
dc.contributor.author Curto A.
dc.contributor.author Cuttaia F.
dc.contributor.author Danese L.
dc.contributor.author Davies R.
dc.contributor.author Davis R.
dc.contributor.author De Bernardis P.
dc.contributor.author De Rosa A.
dc.contributor.author De Zotti G.
dc.contributor.author Delabrouille J.
dc.contributor.author Delouis J.
dc.contributor.author Désert F.
dc.contributor.author Diego J.
dc.contributor.author Dole H.
dc.contributor.author Donzelli S.
dc.contributor.author Doré O.
dc.contributor.author Douspis M.
dc.contributor.author Ducout A.
dc.contributor.author Dupac X.
dc.contributor.author Efstathiou G.
dc.contributor.author Elsner F.
dc.contributor.author Enßlin T.
dc.contributor.author Eriksen H.
dc.contributor.author Falgarone E.
dc.date.accessioned 2018-09-19T20:05:16Z
dc.date.available 2018-09-19T20:05:16Z
dc.date.issued 2016
dc.identifier.issn 0004-6361
dc.identifier.uri https://dspace.kpfu.ru/xmlui/handle/net/142537
dc.description.abstract © ESO, 2016.This paper describes the processing applied to the cleaned, time-ordered information obtained from the Planck High Frequency Instrument (HFI) with the aim of producing photometrically calibrated maps in temperature and (for the first time) in polarization. The data from the entire 2.5-year HFI mission include almost five full-sky surveys. HFI observes the sky over a broad range of frequencies, from 100 to 857 GHz. To obtain the best accuracy on the calibration over such a large range, two different photometric calibration schemes have been used. The 545 and 857 GHz data are calibrated using models of planetary atmospheric emission. The lower frequencies (from 100 to 353 GHz) are calibrated using the time-variable cosmological microwave background dipole, which we call the orbital dipole. This source of calibration only depends on the satellite velocity with respect to the solar system. Using a CMB temperature of TCMB = 2.7255 ± 0.0006 K, it permits an independent measurement of the amplitude of the CMB solar dipole (3364.3 ± 1.5 μK), which is approximatively 1σ higher than the WMAP measurement with a direction that is consistent between the two experiments. We describe the pipeline used to produce the maps ofintensity and linear polarization from the HFI timelines, and the scheme used to set the zero level of the maps a posteriori. We also summarize the noise characteristics of the HFI maps in the 2015 Planck data release and present some null tests to assess their quality. Finally, we discuss the major systematic effects and in particular the leakage induced by flux mismatch between the detectors that leads to spurious polarization signal.
dc.relation.ispartofseries Astronomy and Astrophysics
dc.subject Cosmic background radiation
dc.subject Cosmology: observations
dc.subject Methods: data analysis
dc.subject Surveys
dc.title Planck 2015 results: VIII. High Frequency Instrument data processing: Calibration and maps
dc.type Article
dc.relation.ispartofseries-volume 594
dc.collection Публикации сотрудников КФУ
dc.source.id SCOPUS00046361-2016-594-SID84989826022


Files in this item

This item appears in the following Collection(s)

  • Публикации сотрудников КФУ Scopus [24551]
    Коллекция содержит публикации сотрудников Казанского федерального (до 2010 года Казанского государственного) университета, проиндексированные в БД Scopus, начиная с 1970г.

Show simple item record

Search DSpace


Advanced Search

Browse

My Account

Statistics