dc.contributor.author |
Kiselev V. |
|
dc.contributor.author |
Bolotov A. |
|
dc.contributor.author |
Kornilov D. |
|
dc.date.accessioned |
2018-09-18T20:31:31Z |
|
dc.date.available |
2018-09-18T20:31:31Z |
|
dc.date.issued |
2012 |
|
dc.identifier.issn |
0036-0244 |
|
dc.identifier.uri |
https://dspace.kpfu.ru/xmlui/handle/net/140774 |
|
dc.description.abstract |
The P-V-T parameters for VM-4 and VM-6 vacuum oils are determined in the temperature range of 20-50°C and the pressure range of 1-1000 bar by means of the Tait equation. © Pleiades Publishing, Ltd., 2012. |
|
dc.relation.ispartofseries |
Russian Journal of Physical Chemistry A |
|
dc.subject |
P-V-T parameters |
|
dc.subject |
Tait equation |
|
dc.subject |
Vacuum oils |
|
dc.title |
P-V-T parameters for VM-4 and VM-6 vacuum oils in the temperature range of 20-50°C and the pressure range of 1-1000 bar |
|
dc.type |
Article |
|
dc.relation.ispartofseries-issue |
3 |
|
dc.relation.ispartofseries-volume |
86 |
|
dc.collection |
Публикации сотрудников КФУ |
|
dc.relation.startpage |
523 |
|
dc.source.id |