Kazan Federal University Digital Repository

Effect of nanostructured materials as electrode surface modifiers on the analytical capacity of amperometric biosensors

Show simple item record

dc.contributor.author Medyantseva E.
dc.contributor.author Brusnitsyn D.
dc.contributor.author Varlamova R.
dc.contributor.author Maksimov A.
dc.contributor.author Fattakhova A.
dc.contributor.author Konovalova O.
dc.contributor.author Budnikov G.
dc.date.accessioned 2018-09-18T20:18:56Z
dc.date.available 2018-09-18T20:18:56Z
dc.date.issued 2015
dc.identifier.issn 1070-4272
dc.identifier.uri https://dspace.kpfu.ru/xmlui/handle/net/138626
dc.description.abstract © 2015 Pleiades Publishing, Ltd. Effect of multi-walled carbon nanotubes and silver nanoparticles as surface modifiers of screen-printed graphite electrodes, the basis of amperometric monoamine oxidase biosensors, on their analytical characteristics was studied. The presence of carbon nanotubes and silver nanoparticles was confirmed by UV spectroscopy and scanning electron microscopy. The use of the oxidation current of hydrogen peroxide, the product of oxidative deamination of biogenic amines in the presence of immobilized monoamine oxidase as a representative of the class of oxidoreductases, as the analytical signal made it possible to choose the synthesis method and to suggest ways to deposit the modifiers under study on the electrode surface. The curve of the inhibiting effect of tricyclic antidepressants on the catalytic activity of the immobilized enzyme on the solution pH and amount of modifiers was considered. It was found that the lower limit of the determinable concentrations decreases to a level of 4 × 10<sup>-9</sup> M, the sensitivity coefficient is improved, and the range of determinable concentrations of amitryptiline and imipramine is extended to 1 × 10<sup>-4</sup>-1 × 10<sup>-8</sup> M. It is shown that the suggested biosensors can be used to monitor the residual amounts of medical substances in urine.
dc.relation.ispartofseries Russian Journal of Applied Chemistry
dc.title Effect of nanostructured materials as electrode surface modifiers on the analytical capacity of amperometric biosensors
dc.type Article
dc.relation.ispartofseries-issue 1
dc.relation.ispartofseries-volume 88
dc.collection Публикации сотрудников КФУ
dc.relation.startpage 40
dc.source.id SCOPUS10704272-2015-88-1-SID84928333338


Files in this item

This item appears in the following Collection(s)

  • Публикации сотрудников КФУ Scopus [24551]
    Коллекция содержит публикации сотрудников Казанского федерального (до 2010 года Казанского государственного) университета, проиндексированные в БД Scopus, начиная с 1970г.

Show simple item record

Search DSpace


Advanced Search

Browse

My Account

Statistics