Электронный архив

Flow-injection and sequential injection determination of hydroxypurines on an electrode modified with mixed-valence ruthenium and iridium oxides

Показать сокращенную информацию

dc.contributor.author Shaidarova L.
dc.contributor.author Chelnokova I.
dc.contributor.author Makhmutova G.
dc.contributor.author Degteva M.
dc.contributor.author Gedmina A.
dc.contributor.author Budnikov H.
dc.date.accessioned 2018-09-18T20:14:44Z
dc.date.available 2018-09-18T20:14:44Z
dc.date.issued 2014
dc.identifier.issn 1061-9348
dc.identifier.uri https://dspace.kpfu.ru/xmlui/handle/net/137904
dc.description.abstract Mixed-valence ruthenium (RuO x ) and iridium (IrO x ) oxides and composites on their basis (RuO x -IrO x or IrO x -RuO x ) electrodeposited onto the surface of a glassy carbon electrode exhibit a catalytic activity in the electrooxidation of uric acid, xanthine, and hypoxanthine. The transition from metal oxides to composites of two mixed-valence metal oxides leads to an increase in the catalytic effect of the oxidation of hydroxypurines. The IrO x -RuO x composite demonstrated the highest catalytic activity. Procedures for the amperometric detection of hydroxypurines on this composite electrode under the conditions of flow-injection analysis (FIA) and sequential injection analysis are proposed. A linear dependence of an analytical signal on the analyte concentration is observed in the range 1 × 10-6 to 5 × 10-3 M for uric acid and xanthine and 5 × 10-7 to 5 × 10-3 M for hypoxanthine under FIA conditions and from 5 × 10-7 to 5 × 10-3 M for uric acid and xanthine and 5 × 10-9 to 5 × 10-3 M for hypoxanthine in sequential injection analysis. Under FIA conditions, the sensitivity, rapidity, and performance of the analysis increase compared to the stationary conditions. The advantages of sequential injection analysis over FIA include a lower consumption of the supporting electrolyte; the absence of pumps and connections; and an increase in sensitivity, reproducibility, and rapidity. © 2014 Pleiades Publishing, Ltd.
dc.relation.ispartofseries Journal of Analytical Chemistry
dc.subject chemically modified electrodes
dc.subject electrooxidation of hydroxypurines
dc.subject flow injection analysis
dc.subject mixed-valence ruthenium and iridium oxides
dc.subject sequential injection analysis
dc.title Flow-injection and sequential injection determination of hydroxypurines on an electrode modified with mixed-valence ruthenium and iridium oxides
dc.type Article
dc.relation.ispartofseries-issue 9
dc.relation.ispartofseries-volume 69
dc.collection Публикации сотрудников КФУ
dc.relation.startpage 864
dc.source.id SCOPUS10619348-2014-69-9-SID84906572782


Файлы в этом документе

Данный элемент включен в следующие коллекции

  • Публикации сотрудников КФУ Scopus [24551]
    Коллекция содержит публикации сотрудников Казанского федерального (до 2010 года Казанского государственного) университета, проиндексированные в БД Scopus, начиная с 1970г.

Показать сокращенную информацию

Поиск в электронном архиве


Расширенный поиск

Просмотр

Моя учетная запись

Статистика