Электронный архив

Anisotropic phantoms for quantitative diffusion tensor imaging and fiber-tracking validation

Показать сокращенную информацию

dc.contributor.author Lorenz R.
dc.contributor.author Bellemann M.
dc.contributor.author Hennig J.
dc.contributor.author Il'Yasov K.
dc.date.accessioned 2018-09-18T20:10:43Z
dc.date.available 2018-09-18T20:10:43Z
dc.date.issued 2008
dc.identifier.issn 0937-9347
dc.identifier.uri https://dspace.kpfu.ru/xmlui/handle/net/137303
dc.description.abstract Different fiber materials (hemp, linen, viscose rayon, polyamide and dyneema twine) were tested for their suitability as fiber phantoms for diffusion tensor imaging (DTI) calibration on clinical magnetic resonance imaging systems with common diffusion-weighted echo planar imaging sequences. Additionally, the potential for fiber tracking validation of these fiber phantoms was investigated. For phantom manufacturing the fibers were wound up into a bundle of parallel fibers enwrapped by plastic ribbon. The most homogenously distributed fractional anisotropy (FA) values (0.63 ± 0.10) were determined in the dyneema and polyamide (0.3 ± 0.1) fiber phantom. FA values in the viscose, linen and hemp bundles were at high variations (about 0.2 ± 0.10). The dispersion of the direction of the principal eigenvector in the polyamide and dyneema phantom was less than 7°, for the other fiber phantoms it was over 30°. Thus, the presented results may indicate that polyamide- and dyneema-based fiber phantoms provide the opportunity for verification and validation of DTI sequences on clinical scanner. Additionally, they can be applicable for testing the accuracy of fiber tracking algorithms. A strong parallel alignment of the fibers with a constant compression grade of the fiber bundles could be achieved by machine-made production. This could also provide highly reproducible diffusion properties within the anisotropic fiber phantoms. © 2008 Springer-Verlag.
dc.relation.ispartofseries Applied Magnetic Resonance
dc.title Anisotropic phantoms for quantitative diffusion tensor imaging and fiber-tracking validation
dc.type Article
dc.relation.ispartofseries-issue 4
dc.relation.ispartofseries-volume 33
dc.collection Публикации сотрудников КФУ
dc.relation.startpage 419
dc.source.id SCOPUS09379347-2008-33-4-SID58449110928


Файлы в этом документе

Данный элемент включен в следующие коллекции

  • Публикации сотрудников КФУ Scopus [24551]
    Коллекция содержит публикации сотрудников Казанского федерального (до 2010 года Казанского государственного) университета, проиндексированные в БД Scopus, начиная с 1970г.

Показать сокращенную информацию

Поиск в электронном архиве


Расширенный поиск

Просмотр

Моя учетная запись

Статистика