Kazan Federal University Digital Repository

Polyaniline-DNA based sensor for the detection of anthracycline drugs

Show simple item record

dc.contributor.author Shamagsumova R.
dc.contributor.author Porfireva A.
dc.contributor.author Stepanova V.
dc.contributor.author Osin Y.
dc.contributor.author Evtugyn G.
dc.contributor.author Hianik T.
dc.date.accessioned 2018-09-18T20:10:22Z
dc.date.available 2018-09-18T20:10:22Z
dc.date.issued 2015
dc.identifier.issn 0925-4005
dc.identifier.uri https://dspace.kpfu.ru/xmlui/handle/net/137240
dc.description.abstract © 2015 Elsevier B.V. All rights reserved. New approach of the detection of anthracycline preparations intercalating native DNA has been proposed and realized in the assembly of electrochemical sensor. Glassy carbon was covered with polyaniline obtained by electropolymerization in the presence of native DNA and oxalic acid as doping agents. As was shown by impedimetric and voltammetric measurements, the surface coating obtained showed extended pH range of electrochemical activity and retained ability to interact with specific intercalators. The incubation of the sensor with anthracycline preparations resulted in regular decrease of electron transfer resistance and suppression of redox probe current (ferricyanide anion). In optimal conditions, the detection limits of 0.01 nM doxorubicin, 0.1 nM daunorubicin and 0.2 nM idarubicin were achieved. The replacement of oxalic acid with sulfuric acid as polymerization media as well as thermal denaturation of DNA resulted in disappearance of the response. The selectivity of DNA interaction detection was higher in weakly acidic media for impedimetric measurements and in HEPES, pH 7.0, for voltammetric detection. Albumin, blood plasma electrolytes and sulfanylamides do not interfere with anthracycline measurements. The electrochemical sensor developed was tested in the determination of doxorubicin in commercial preparation with 91-93% recovery.
dc.relation.ispartofseries Sensors and Actuators, B: Chemical
dc.subject Anthracycline pharmaceuticals
dc.subject DNA intercalator
dc.subject DNA sensor
dc.subject Electrochemical sensor
dc.subject Electropolymerization
dc.subject Polyaniline
dc.title Polyaniline-DNA based sensor for the detection of anthracycline drugs
dc.type Article
dc.relation.ispartofseries-volume 220
dc.collection Публикации сотрудников КФУ
dc.relation.startpage 573
dc.source.id SCOPUS09254005-2015-220-SID84934942191


Files in this item

This item appears in the following Collection(s)

  • Публикации сотрудников КФУ Scopus [24551]
    Коллекция содержит публикации сотрудников Казанского федерального (до 2010 года Казанского государственного) университета, проиндексированные в БД Scopus, начиная с 1970г.

Show simple item record

Search DSpace


Advanced Search

Browse

My Account

Statistics