Электронный архив

Application of constant-current coulometry for estimation of plasma total antioxidant capacity and its relationship with transition metal contents

Показать сокращенную информацию

dc.contributor.author Ziyatdinova G.
dc.contributor.author Voloshin A.
dc.contributor.author Gilmutdinov A.
dc.contributor.author Budnikov H.
dc.contributor.author Ganeev T.
dc.date.accessioned 2018-09-18T20:09:31Z
dc.date.available 2018-09-18T20:09:31Z
dc.date.issued 2006
dc.identifier.issn 0731-7085
dc.identifier.uri https://dspace.kpfu.ru/xmlui/handle/net/137094
dc.description.abstract Simple and express coulometric method for the evaluation of the total antioxidant capacity (TAC) of human plasma based on the reaction with electrogenerated bromine is applied. TAC of plasma from patients with different ethiology of chronic renal failure was observed. The levels of antioxidant capacity for venous and arterial plasma are authentically different (15 ± 1 kCl/L versus 11.7 ± 0.7 kCl/L, p < 0.01). The application of Vitamin E and ximedon as an antioxidant treatment significantly increase TAC level of plasma. Free liposoluble antioxidants in plasma in α-tocopherol units was determined. Redox potential of plasma is measured and its correlation with lg(TAC) is obtained. Transition metal contents of Fe, Cu, Mn, Ni, and Cr in plasma of patients with chronic renal failure is significantly higher than that for a control group. Correlation analysis has shown negative linear regression between TAC value and transition metals concentration in plasma. This confirms interrelation of processes with participation of free radicals, antioxidants and transition metals as donors of electrons in chain radical processes. Moreover, it shows utility of common parameters, TAC for example, for estimation of efficiency of antioxidant defense system in living organism, in particular its antioxidant status. © 2005 Elsevier B.V. All rights reserved.
dc.relation.ispartofseries Journal of Pharmaceutical and Biomedical Analysis
dc.subject Antioxidant therapy
dc.subject Atomic absorbtion spectroscopy
dc.subject Chronic renal failure
dc.subject Coulometric titration
dc.subject Human plasma
dc.subject Redox potential
dc.subject Total antioxidant capacity
dc.subject Transition metals
dc.title Application of constant-current coulometry for estimation of plasma total antioxidant capacity and its relationship with transition metal contents
dc.type Article
dc.relation.ispartofseries-issue 4
dc.relation.ispartofseries-volume 40
dc.collection Публикации сотрудников КФУ
dc.relation.startpage 958
dc.source.id SCOPUS07317085-2006-40-4-SID32944463736


Файлы в этом документе

Данный элемент включен в следующие коллекции

  • Публикации сотрудников КФУ Scopus [24551]
    Коллекция содержит публикации сотрудников Казанского федерального (до 2010 года Казанского государственного) университета, проиндексированные в БД Scopus, начиная с 1970г.