dc.contributor.author |
Ziyatdinova G. |
|
dc.contributor.author |
Budnikov G. |
|
dc.contributor.author |
Pogorel'tsev V. |
|
dc.date.accessioned |
2018-09-17T21:08:27Z |
|
dc.date.available |
2018-09-17T21:08:27Z |
|
dc.date.issued |
2004 |
|
dc.identifier.issn |
1061-9348 |
|
dc.identifier.uri |
https://dspace.kpfu.ru/xmlui/handle/net/134572 |
|
dc.description.abstract |
Procedures for determining lipoic acid by voltammetry and coulometric titration with electrogenerated halogens using the biamperometric indication of the titration end-point were developed. Possible mechanisms of lipoic acid oxidation with electrogenerated halogens are discussed. Microgram amounts of lipoic acid were determined in model solutions with an RSD of 1-2%. The analytical range of lipoic acid found by voltammetry at a glassy-carbon electrode lies between 1.15 × 10-5 and 1.73 × 10 -4 M. The detection limit for lipoic acid is 5.75 × 10 -6 M. |
|
dc.relation.ispartofseries |
Journal of Analytical Chemistry |
|
dc.title |
Electrochemical determination of lipoic acid |
|
dc.type |
Article |
|
dc.relation.ispartofseries-issue |
3 |
|
dc.relation.ispartofseries-volume |
59 |
|
dc.collection |
Публикации сотрудников КФУ |
|
dc.relation.startpage |
288 |
|
dc.source.id |
SCOPUS10619348-2004-59-3-SID3543004728 |
|