Электронный архив

Application of the generalized mean value function to the statistical detection of water in decane by near-infrared spectroscopy

Показать сокращенную информацию

dc.contributor.author Nigmatullin R.
dc.contributor.author Moroz A.
dc.contributor.author Smith G.
dc.date.accessioned 2018-09-17T20:43:47Z
dc.date.available 2018-09-17T20:43:47Z
dc.date.issued 2005
dc.identifier.issn 0378-4371
dc.identifier.uri https://dspace.kpfu.ru/xmlui/handle/net/133955
dc.description.abstract The generalized mean value (GMV) function, defined as GN(p)=(ΔN(p))1/ p(where ΔN(p) is the absolute value of the moment of the pth order), was used here to differentiate between statistically close random sequences or those sequences containing large numbers of measured points (N≧1). The approach taken was to find (with the help of the eigen-coordinates method) the approximate analytical function for any GN(p), and in so doing demonstrate that it is inherently possible to express quantitatively the reduced characteristics of any random sequence, in terms of the 'universal' set of fitting parameters defined by this function. The introduction of a 'universal' set of the reduced parameters in the moment space then provides the instrument for the comparison of different random sequences. Applications for this new method are evident for many branches of the analytical sciences, but especially in cases when visual 'labels' (e.g. resonance lines), which serve as an indication of the presence of an additive, are either absent or 'contaminated' strongly by noise. Those fitting parameters from the approximate analytical expression, which depend on the concentration of the small additive can then be used for the construction of the quasi-monotonic line, defined as the calibration curve. Real experiments based on the treatment of near-infrared (NIR) spectra obtained for decane (the initial matrix) with water (the additive) confirm the efficiency of this simple approach. In contrast, the more conventional statistical method, based on cluster analysis, failed to establish the desired calibration curve. This simple and universal approach, which is free from model assumptions, can be used for any set of random sequences (e.g. spectrograms) if it is necessary to compare them quantitatively with each other. © 2005 Elsevier B.V. All rights reserved.
dc.relation.ispartofseries Physica A: Statistical Mechanics and its Applications
dc.subject A. Generalized mean value
dc.subject A. Higher moments
dc.subject B. Random sequences
dc.subject C. Eigen-coordinates method
dc.title Application of the generalized mean value function to the statistical detection of water in decane by near-infrared spectroscopy
dc.type Article
dc.relation.ispartofseries-issue 2-4
dc.relation.ispartofseries-volume 352
dc.collection Публикации сотрудников КФУ
dc.relation.startpage 379
dc.source.id SCOPUS03784371-2005-352-24-SID18144390596


Файлы в этом документе

Данный элемент включен в следующие коллекции

  • Публикации сотрудников КФУ Scopus [24551]
    Коллекция содержит публикации сотрудников Казанского федерального (до 2010 года Казанского государственного) университета, проиндексированные в БД Scopus, начиная с 1970г.

Показать сокращенную информацию

Поиск в электронном архиве


Расширенный поиск

Просмотр

Моя учетная запись

Статистика