Kazan Federal University Digital Repository

Expected accuracy of a small telescope like PZT for observations of vertical gravity gradient and lunar rotation

Show simple item record

dc.contributor.author Hanada H.
dc.contributor.author Tsuruta S.
dc.contributor.author Asari K.
dc.contributor.author Araki H.
dc.contributor.author Noda H.
dc.contributor.author Kashima S.
dc.contributor.author Funazaki K.
dc.contributor.author Satoh A.
dc.contributor.author Taniguchi H.
dc.contributor.author Kato H.
dc.contributor.author Kikuchi M.
dc.contributor.author Sasaki H.
dc.contributor.author Hasegawa T.
dc.contributor.author Gusev A.
dc.date.accessioned 2018-09-19T22:55:54Z
dc.date.available 2018-09-19T22:55:54Z
dc.date.issued 2016
dc.identifier.uri https://dspace.kpfu.ru/xmlui/handle/net/145780
dc.description.abstract © State Research Center of the Russian Federation Concern CSRI Elektropribor, JSC, 2016.Development of the PZT type telescope for observations of gravity gradient and lunar rotation was being made, and a Bread Board Model (BBM) for ground experiments was completed. Some developments were made for the BBM such as a new tripod and a stable mercury pool. We performed laboratory experiments and field observations from August to September of 2014, in order to check the total system of the telescope and the software. It is also investigated how the ground vibrations affect the stellar position on CCD. The results of the preliminary observations showed that the variation of stellar positions was better than 0.1 arc-second in the laboratory and was about 0.4 arc-seconds in the case of field observations. The difference in standard deviation (SD) of the variation is partly due to different signal to noise ratio (SNR) of star images. There was a strong correlation between the SD and SNR. There are, on the other hand, periodic components in the range lower than 6 Hz in a data from continuous record taken by a video camera. The variation became much smaller after removing the periodic components.
dc.subject Lunar rotation
dc.subject Photographic Zenith Tube (PZT)
dc.subject Vertical gradient of gravity Deflection of the vertical
dc.title Expected accuracy of a small telescope like PZT for observations of vertical gravity gradient and lunar rotation
dc.type Conference Paper
dc.collection Публикации сотрудников КФУ
dc.relation.startpage 220
dc.source.id SCOPUS-2016-SID84973547880


Files in this item

This item appears in the following Collection(s)

  • Публикации сотрудников КФУ Scopus [24551]
    Коллекция содержит публикации сотрудников Казанского федерального (до 2010 года Казанского государственного) университета, проиндексированные в БД Scopus, начиная с 1970г.

Show simple item record

Search DSpace


Advanced Search

Browse

My Account

Statistics